High Purity and Certificates of Analysis: Research Material Acceptance
Evaluate a purity percentage together with its definition and analytical scope. A catalogue value, sample certificate and results for the shipped lot are different records. Define the evidence needed for acceptance before ordering the material.
Pre-quotation checklist
| Check | Information to request | Purpose |
|---|---|---|
| Purity claim | Percentage, calculation basis and exclusions | The same percentage can refer to different analytical scopes |
| Critical impurities | Experiment-relevant elements and maximum limits | Overall purity may not control a particular critical element |
| Analysis scope | Tested elements, method, units and reporting limits | Distinguish unlisted or unmeasured constituents |
| Lot identification | Product code, lot number and document date | Connect the record to the delivered material |
| Physical properties | Form, particle size, geometry, density as applicable | Chemical purity does not define physical acceptance |
| Document type | Sample CoA, lot-specific CoA or general technical sheet? | Separate quotation information from delivery evidence |
What do 3N, 4N and 5N mean?
In common notation, 3N denotes 99.9%, 4N 99.99% and 5N 99.999%. This shorthand alone does not identify which impurities enter the calculation. Where “metals basis”, “trace metals basis” or a rare-earth-based ratio is stated, request the calculation scope and any separately reported constituents.
Read the analytical panel and limits
For an experiment-critical element, the name alone is insufficient: a result, unit and limit are needed. “Not detected” or a result reported below a limit should not be interpreted as zero concentration. Confirm that the analytical method can substantiate your required limit.
Define material form separately
Specify target geometry and any density/bonding requirement, pellet or piece dimensions for evaporation sources, and particle-size/distribution requirements for powders. Do not assume that a chemical certificate covers every physical property of the product.
Agree documentation scope during quotation
A sample document may support initial review but should not be treated as the report for the shipped lot. Adesis confirms available analysis and measurement records for the specific product and order. Identify any special analysis, independent testing or additional reports, with methods and acceptance limits, before order.
Copyable RFQ specification template
Complete the fields relevant to your experiment; mark unknowns as “technical recommendation requested”. Paste the text into the RFQ technical notes and attach drawings or specifications separately.
Material / compound / composition: Required purity and calculation basis: Critical impurities and maximum limits: Required analytical method / reporting limits: Physical form and dimensions / particle range: Required CoA: sample / lot-specific: Other required measurement reports: Lot identification and packaging requirements: Quantity and acceptable alternatives: